46.13 SNA SPM do DB2 Falhou ao Iniciar Após a Inicialização do Windows

Se estiver utilizando o Microsoft SNA Server Versão 4 SP3 ou posterior, verifique se o SNA SPM do DB2 iniciou adequadamente após a inicialização. Verifique o arquivo \sqllib\<nome da instância>\db2diag.log para obter entradas similares ao seguinte:

2000-04-20-13.18.19.958000   Instance:DB2   Node:000
PID:291(db2syscs.exe)   TID:316   Appid:none
common_communication  sqlccspmconnmgr_APPC_init   Probe:19 
SPM0453C  Sync point manager did not start because Microsoft SNA Server has not 
been started.
 
2000-04-20-13.18.23.033000   Instance:DB2   Node:000
PID:291(db2syscs.exe)   TID:302   Appid:none
common_communication  sqlccsna_start_listen   Probe:14
DIA3001E "SNA SPM" protocol support was not successfully started.
 
2000-04-20-13.18.23.603000   Instance:DB2   Node:000
PID:291(db2syscs.exe)   TID:316   Appid:none
common_communication  sqlccspmconnmgr_listener   Probe:6 
DIA3103E Error encountered in APPC protocol support. APPC verb "APPC(DISPLAY 1
BYTE)". Primary rc was "F004". Secondary rc was "00000000".

Se tais entradas existirem no db2diag.log, e os registros de tempo corresponderem à hora de reinicialização mais recente, você deve:

  1. Solicitar o db2stop.
  2. Iniciar o serviço SnaServer (se ainda não o tiver feito).
  3. Solicitar o db2start.

Verifique o arquivo db2diag.log novamente para ver se as entradas não estão mais anexadas.