System requirements

To run the Rational Synergy 7.1 server with the IBM Informix database:

  • One of the following operating systems must be installed on your computer:
    • IBM AIX® 6.1
    • Red Hat® Enterprise Linux 5 (32-bit or 64-bit on x86 architecture)
    • Solaris® 10
    • SUSE® Linux Enterprise Server 10 SP2 (32-bit or 64-bit on x86 architecture)
    • Windows® Server 2003 R2 Standard or Enterprise Edition (32-bit or 64-bit)
    • Windows XP Professional SP3 (for evaluation purposes only)
    • VMWare® ESX Server™ 3.5 running Windows Server 2003 R2 Standard or Enterprise Edition (32-bit or 64-bit)

 

  • The minimum hardware requirements are:
    • A multi-processor or multi-core processor server class machine
    • 4 GB RAM for the Rational Synergy server
    • 900 MB free disk space

 

  • IBM Rational Directory Server 5.0, 5.1, or 5.x must be installed and operational
  • IBM Rational License Server TL 2.0 or Telelogic License Server 1.5 must be installed and operational

To run the Rational Synergy 7.1 server with an Oracle® database:

  • One of the following operating systems must be installed on your computer:
    • IBM AIX 6.1
    • Red Hat Enterprise Linux 5 (32-bit or 64-bit on x86 architecture)
    • Solaris 10

 

  • The minimum hardware requirements are:
    • A multi-processor or multi-core processor server class machine
    • 8 GB RAM for the Rational Synergy server
    • 900 MB free disk space

 

  • IBM Rational Directory Server 5.0, 5.1, or 5.x must be installed and operational
  • IBM Rational License Server TL 2.0 or Telelogic License Server 1.5 must be installed and operational
  • Oracle Database 10g Release 2 (64 bit) must be installed and operational

To run the Rational Synergy 7.1 client:

  • One of the following operating systems must be installed on your computer:
    • IBM AIX 6.1
    • Red Hat Enterprise 5 (32-bit or 64-bit on x86 architecture)
    • Solaris 10
    • SUSE® Linux Enterprise Server 10 SP2
    • Windows 7 (32-bit and 64-bit)
    • Windows XP Professional SP3
    • Windows Vista Enterprise Edition SP3
    • Windows Server 2003 R2 Standard or Enterprise Edition (32-bit or 64-bit)
    • Citrix XenApp 5 on Windows Server 2003 Enterprise R2 (32-bit or 64-bit)

 

  • One of the following browsers must be installed on your computer:
    • Internet Explorer 8.0 for Windows 7 clients
    • Internet Explorer 6 SP2 or 7.0 or Firefox 3 for Windows XP and Windows 2003 clients
    • Internet Explorer 7.0 or Firefox 3 for Windows Vista SP1 clients
    • Firefox 2.0 for IBM AIX clients
    • Firefox 3.0 for Red Hat Enterprise Linux, Solaris, and SUSE Enterprise Linux clients

 

  • The minimum hardware requirements are:
    • A Windows computer with a Pentium II 500 MHz single processor (for optimal performance: Pentium III 733+ MHz) OR a UNIX computer with a 200 MHz single processor (for optimal performance: 400+ MHz)
    • 1 GB memory (for optimal performance: 2 GB)
    • 750 MB free disk space

 

For additional information on system requirements, visit the Rational Support website at: http://www.ibm.com/software/awdtools/synergy/sysreqs


Operating system locales supported by Rational Synergy 7.1

Rational Synergy 7.1 is certified only in the C locale. IBM supports use in any locale using the Latin-1 character set or the Windows extension CP 1252; however, such locales have not been tested. Use in locales using non-Latin-1 character sets is not supported. Rational Synergy displays dates and times in locale-appropriate formats, but some Rational Synergy interfaces accept dates and times as input only in US formats. Rational Synergy does not adapt messages, numeric formats, or sorting orders according to the locale.


Compatible products

Rational Synergy 7.1 with Fix Pack 7.1.0.2 is compatible with the following products:

  • IBM Rational Change 5.2 with Fix Pack 5.2.0.4
  • IBM Rational Directory Server 5.0 or 5.1
  • IBM Rational License Server TL 2.0 or Telelogic License Server 1.5

Rational Synergy 7.1 with Fix Pack 7.1.0.2 is DCM-compatible with the following versions:

  • IBM Rational Synergy 7.1
  • Telelogic Synergy 7.0
  • Telelogic Synergy 6.5 SP2
  • Telelogic Synergy 6.4 SP1
  • Telelogic Synergy 6.6a

Previous releases of Rational Synergy require patches to support DCM compatibility with Rational Synergy 7.1. See the Rational Support website for more information.



Installing Rational Synergy Fix Pack 7.1.0.2

Rational Synergy Fix Pack 7.1.0.2 requires Rational Synergy 7.1 with Fix Pack 7.1.0.1 to be installed. Fix Pack 7.1.0.2 does not contain fixes from Fix Pack 7.1.0.1.

To install Rational Synergy 7.1 and the subsequent Fix Packs:

Release

Information

Rational Synergy 7.1

Log in to IBM Passport Advantage to download platform-specific installation images for Rational Synergy 7.1 or to request a physical media kit. See the IBM Rational Synergy Installation Guide for detailed directions about installation. The documentation is available online at the Rational Information Center.

Rational Synergy Fix Pack 7.1.0.1

Log in to the Rational Support Site to download Rational Synergy Fix Pack 7.1.0.1. The Fix Pack requires an existing Rational Synergy 7.1 installation. The Fix Pack contains a readme with installation instructions.
Rational Synergy Fix Pack 7.1.0.1 includes the following patches: 7.1 iFixes 01 and 03.

Rational Synergy Fix Pack 7.1.0.2

Log in to the Rational Support Site to download Rational Synergy Fix Pack 7.1.0.2. The Fix Pack requires an existing Rational Synergy 7.1 installation with Fix Pack 7.1.0.1 already installed. The Fix Pack contains a readme with installation instructions.
Rational Synergy Fix Pack 7.1.0.2 includes the following patches: 7.1.0.1 iFixes 01, 02, and 03. See details about the fixes in iFix 7.1.0.1.03 on the support site.


Obtaining a license for Rational Synergy 7.1

Rational Synergy 7.1 uses the IBM Rational License Server TL, which is a FLEXlm-based license server that manages licenses for heritage Telelogic products.

If you have a Telelogic Synergy 7.0 installation, you do not need a new license. If you have a Telelogic Synergy installation previous to 7.0, you must install the latest Rational License Server TL and request a new license. To obtain the license server, log in to Passport Advantage. See the Rational Support website for information on how to get your Rational license keys.


What's new in version 7.1

Changes to Rational Synergy 7.1 are summarized below.


Branding

The Telelogic Synergy product name was changed to Rational Synergy. The splash screen and About dialog box were updated. On Windows, the installation path, Start menu entry, and desktop icons were updated.


Improved support for component-based development

The following improvements were made to support component-based development in Rational Synergy:

  • Switch to a new version of a subcomponent is easier. When a user uses a new version of a subcomponent project or product, the new version is added to the current task. This ensures that when the user checks in changes, the changes are propagated through the normal development and test lifecycle to other team members.
  • Using new subcomponents and setting up rules for using new components is easier.

    When a build manager creates a baseline, Rational Synergy automatically creates two component tasks, one for projects and one for products. The component tasks are a handle for using those components in other releases.

    The Process Rules dialog box provides a new dialog box to easily find and add component tasks to the process rules for a given release. Build managers can set up rules, such as:
    • Include subcomponent projects from a specific release and baseline
    • Include the latest published products from a specific release
    • Include the newest released projects and products of a subcomponent (from any release)
    • Include the latest published projects from a specific release, any component (for example, a team who has many subcomponents with two-week release cycles can set up rules to include all subcomponents for release */week42, where * can be any component)


The creation of component tasks can be turned off per release if it is not needed, for example, if a specific component release is not meant to be reusable by other teams.

Upgrade does not automatically create component tasks for baselines that were created prior to the upgrade. A new command is provided to create component tasks for pre-existing baselines as needed. See the "ccm baseline" command for details. This command is available in both the traditional and Web mode CLIs. However, the command is only documented in the Rational Synergy CLI Help - web mode document (English version or Japanese version).

DCM supports the transfer of component tasks. They are included automatically when a baseline is transferred, or you can add a component task directly to a transfer set to transfer that component. You must install patches to previous releases in order to exchange data between Rational Synergy 7.1 and those releases using DCM.

  • Rational Synergy 7.1 provides full support for baselines containing mixed releases. By default, when you create a baseline for a project hierarchy that contains mixed releases, the baseline includes all projects and releases in the hierarchy.

    Starting in Rational Synergy 7.1, the subcomponents with different releases can use the top-level baseline; update the process rules to refer to the hierarchy baseline. A new command option is provided for copying the baseline rules from the parent process rules to the other process rules; see "ccm process_rule -copy -baseline_rules_only".
  • In previous releases, when you created a baseline, if Telelogic Synergy detected that some of the tasks in the project grouping properties were not included in all of the projects, those tasks were marked untrusted and continued to be shown in the "tasks on top of the baseline" in the Project Grouping Properties. The update operation still includes the tasks in the project grouping, but they are no longer shown in tasks on top of the baseline, nor used in baseline compare, giving a more accurate view of which tasks were introduced in the newer baseline.

    The Rational Synergy CLI provides the ability to view the additional untrusted tasks.
  • When updating a project, if there are no candidates for the root directory, the update operation will give an error and stop. This prevents the root directory and all members from disappearing, for example, when there is no baseline to provide a root directory candidate. This change applies to all interfaces.


Usability improvements

The History dialog box was updated to manage a complex history containing many versions. A new macro view provides context and improved navigation. A new list view provides improved sorting and filtering to enable users to quickly find a specific version and navigate to it. Show only the selected version, predecessors and successors with one click to traverse complex histories. Increase or decrease the font size and number of versions shown with one click.

Selecting release values was improved. By default, Rational Synergy saves the most recently-used release values at the top of the Release drop-down list so that users do not need to expand the release tree. These release values are referred to as favorites. Users can set preferences for how many release favorites will appear and which values should be permanently displayed in the Release drop-down list.


Support for link-based work areas in Web Mode

Link-based work areas are now supported for UNIX clients running in Web Mode. Link-based work areas in Web Mode behave the same as link-based work areas in Traditional Mode, and are fully supported in the Rational Synergy graphical and command line interfaces.

Note: Rational Synergy Web Mode clients running over a Wide Area Network (WAN) require NFS visibility from the client system to the Rational Synergy server system in order to use link-based work areas.


Updates to the Rational Synergy CLI for Web Mode

The Rational Synergy CLI no longer requires the user to type the password as an option to the "ccm start" command on Windows. A user can use the new command "ccm set_password" to save an encrypted copy of his or her password to a file. The new option "ccm start -fpw <file>" reads and uses the password from the specified file. This provides a more secure option for Windows-based scripts.

The Rational Synergy CLI has the following improvements in version 7.1:

  • The "ccm attr -copy" subcommand was implemented.
  • The "ccm baseline" command was extended to support creating and displaying component tasks:
    • A new "ccm baseline -create_component_tasks" subcommand can be used to create component tasks for a baseline.
    • "ccm baseline -show" now shows component tasks if they exist.
  • The "ccm copy_project", "ccm create -t project", and "ccm wa" commands were updated with options to support link-based work areas on UNIX.
  • The "ccm dcm" subcommands and options were completed, and several new commands were added, including:
    • ccm dcm -delete -packages
    • ccm dcm -modify -settings
    • ccm dcm -show -el
    • ccm dcm -show -packages
    • ccm dcm -show -receive_lock
    • ccm dcm -show -settings
  • The "ccm delimiter" command was extended to show the version delimiter.
  • The "ccm finduse" command was completed and extended to support the following subcommands:
    • ccm finduse -folder
    • ccm finduse -folder_template
    • ccm finduse -change_request
    • A new scope for finding process rules using an object was added.
  • The "ccm folder -finduse" command option was completed.
  • The "ccm folder", "ccm folder_template", and "ccm task -query" subcommands were extended to support convenient querying for component tasks.
  • A new "ccm process" command is available to enable creating and maintaining processes from the command line:
    • ccm process -copy
    • ccm process -create
    • ccm process -delete
    • ccm process -list
    • ccm process -modify
    • ccm process -show
  • A new "ccm process_rule -copy_baseline_rules_only" command was implemented.
  • The "ccm project_grouping" command was completed and extended:
    • New "ccm pg -refresh_baseline_and_tasks" subcommand
    • New "ccm pg -compare" subcommands
    • New "ccm pg -set_custom_baseline" subcommand
    • The "ccm pg -show" subcommand supports showing tasks on top of the baseline.
  • The "ccm project_purpose -delete" and "ccm project_purpose -modify" subcommands were implemented.
  • The "ccm release" command was extended to support component tasks:
    • ccm release -create
    • ccm release -modify
    • ccm release -show
  • A new "ccm show_servers" command shows CCM servers.
  • The "ccm soad" and "ccm soad_scope" subcommands were completed, including:
    • ccm soad -preview
    • ccm soad -delete
    • ccm soad_scope -create
    • ccm soad_scope -delete
    • ccm soad_scope -list
    • ccm soad_scope -modify
  • The information formats for various objects was extended to show:
    • Directory entries for directories and projects in verbose mode
    • Component tasks for baselines in verbose mode
    • Baseline project for projects
    • Component tasks for release definitions

For a detailed list of improvements to the Rational Synergy CLI in release 7.1, and information about upgrading to the Rational Synergy CLI, visit the Rational Support website.


Improved administration for Web Mode

By default, a single CCM server serves all Rational Synergy databases. For improved scalability when supporting large numbers of users, you can create additional CCM servers on different physical servers to serve different Rational Synergy databases. All back-end Rational Synergy sessions will run on the physical server that hosts the CCM server.

Rational Synergy 7.1 improves the ability to manage which CCM servers serve which Rational Synergy databases with the following features:

  • When creating a new Rational Synergy database using the unpack, load, or upgrade commands, specify the CCM server to serve the database using the new -url CCMServerAddress option.
  • Reassign Rational Synergy databases to different servers using the new web administration interface. To use the web administration interface, navigate to the URL CCMServerAddress/admin. The page shows all databases and their assigned servers. If a database is actively being served by a server, you must login to the admin interface for that server in order to change it.

A Rational Synergy end user can now change his or her RDS password via the Rational Synergy CCM server by navigating to the URL CCMServerAddress/user.


Deployment of Windows clients

Rational Synergy Windows client users can now install and patch their Rational Synergy client installations using the Rational Synergy deployment feature without having Administrator privilege on the Windows desktop.

If the user installing Rational Synergy has Administrator privilege, the Rational Synergy client is installed for all users of the local machine, and requires the end user to have Administrator privilege to update the client installation in the future. This is how the client behaved in previous releases.

If the user installing Rational Synergy does not have Administrator privilege, the Rational Synergy client is installed for the current user only. The registry entry is stored under HKEY_CURRENT_USER rather than HKEY_LOCAL_MACHINE. This enables the user to automatically update/patch his or her own client from the server using the Rational Synergy deployment feature.

Note: Windows Vista has additional security restrictions that may prevent automatic deployment.


Large file support

Rational Synergy now supports files larger than 2 GB on all platforms and in all user interfaces.


New archiver

Rational Synergy 7.1 includes a new underlying archiver used to archive source files. The new archiver is scalable, reliable, and fast, and is used for both ascii and binary data types. This change is transparent to all users except the administrator.

Starting in Rational Synergy 7.1, archiving is asynchronous for fast file check in. Upon check in, source files are synchronized from the work area to the Rational Synergy server, but the check in operation does not wait until the file is archived before completing. This improves the performance of check in, especially for large files.

All related tools and commands such as "ccm clean_cache" and "ccm archive_check" were updated to behave appropriately to work with the new archiver and asynchronous archiving behavior.

Each database has one back-end session dedicated to archiving checked-in files for all users of that database. Administrators may want to configure the CCM server to increase the number of back-end sessions for a given database to account for this dedicated session. See the IBM Rational Synergy Administration Guide for more information about configuring the server.


What's new in Fix Pack 7.1.0.1

Changes to Rational Synergy Fix Pack 7.1.0.1 from the previous release are summarized below.

  • The Fix Pack contains fixes to many defects submitted against previous releases; see fixed problems.
  • The Rational Synergy client is now supported on Windows 7.
  • The Rational Synergy client is now supported on the Federal Desktop Core Configuration (FDCC), a list of security settings recommended by the National Institute of Standards and Technology for general-purpose microcomputers that are connected to the network of a United States government agency.
  • Trusted Client support is now available for Web Mode to enable Common Access Card (CAC) support via Windows Active Directory. This feature was available in Traditional Mode, and is now supported for Web Mode as well.
  • It is possible to set which CCM server manages which Rational Synergy database via the command line interface, for scripting purposes
  • The history dialog box now shows the relationship from a project's baseline rather than the project from which it was originally copied.

What's new in Fix Pack 7.1.0.2

Changes to Rational Synergy Fix Pack 7.1.0.2 from the previous release are summarized below.

  • The Fix Pack contains fixes to several defects; see fixed problems.
  • Rational Synergy Fix Pack 7.1.0.2 adds the Open Services for Lifecycle Collaboration (OSLC) SCM 1.0 REST API. See http://open-services.net/bin/view/Main/ScmHome for more information.
  • If Rational Synergy login fails because the RDS password has expired, Rational Synergy now gives a message to that effect rather than giving the message "Invalid user or password." See RFE 6598.

Notification for Future Releases

This section provides advance notication of changes in future versions of Rational Synergy.

  • The Rational Synergy Classic graphical user interface (GUI) will no longer be available. The Rational Synergy GUI replaces Rational Synergy Classic.
  • The Rational Synergy Classic command line interface (CLI) will no longer be available. The Rational Synergy CLI replaces Rational Synergy Classic CLI.
  • The Rational Synergy Traditional Mode communication architecture will no longer be available. Rational Synergy Web Mode replaces Traditional Mode. This change should be transparent to users.
  • Object-based update (also referred to as object-based reconfigure) will no longer be supported. Task-based update replaces object-based update.
  • Manual reconfigure properties will no longer be supported. Process rules replace manual reconfigure properties. More information will be provided in the next release for teams converting from manual reconfigure properties to process rules.

Known problems

Visit the IBM Support site for an updated list of known problems.


Fixed problems

Fixed in Rational Synergy Fix Pack 7.1.0.1
Fixed in Rational Synergy Fix Pack 7.1.0.2

The following problems were fixed in Rational Synergy Fix Pack 7.1.0.1.

APAR

ID

Synopsis

N/a

J#5127

Deleting a product fails if it has a successor

N/a

J#5202

Can't select text with Shift-Click in Synergy client

N/a

J#5697

Labels in Tasks tab of Process Rules Compare dialog should wrap if they are too long to display

N/a

J#5737

It is not possible to set the 'used for' value when creating a new purpose using only the keyboard

N/a

J#6459

No message in status line or log when adding a task to a folder (process rule)

N/a

M#6714

Cannot use a different version of the root directory from the CLI

N/a

J#6965

Starting the GUI with the -d option after starting with an invalid database path ignores the -d option

N/a

J#7005

Release value auto-completion shows double characters if you type too fast

N/a

J#7025

After editing only part of the release value in the properties dialog, the change is not always saved

N/a

M#8096

ccm move command preserves only the immediate directory's members, not the whole tree below

N/a

M#11614

attrange.dft file (containing default attribute range values) is only reloaded if has a new timestamp

N/a

M#13059

Cannot delete a task if the task is used in a folder, project, or project grouping that the user cannot modify

N/a

M#13140

Cannot check out another user's file from checkpoint state even in role ccm_admin

N/a

R#17103

Make history view show project baseline rather than project's predecessor

N/a

R#17844

Compare button not always active in Synergy history dialog when two versions are selected

N/a

R#19106

User in developer role can disable group object

N/a

R#20022

Need a "-unique" sorting capability for ccm query results

N/a

R#20340

"Module not found: uimuid" message in log file during dcm receive operation

N/a

R#21527

Checking out a product gives erroneous warning that a task is required

N/a

R#21825

When a project for a new project grouping is checked out and updated, the project grouping is refreshed twice (not efficient)

N/a

R#22993

Unhandled runtime exception when clicking the Objects tab in Synergy client

N/a

R#23671

Starting Synergy from the command line with -d argument puts the specified database path into the database field with only one preceding backslash

N/a

R#25931

User can enter any length of text into the ‘With Version Matching’ field of process rule properties dialog, even though the version string size is limited

N/a

R#26284

When copying a folder, the name should be "Copy Of "

N/a

R#26298

Drag-and-drop of a checked out directory into a checked in directory reports an Unhandled Runtime Exception in a migrated project

N/a

R#26528

Engine startup with ESD leaves a defunct process

N/a

R#26736

Trailing spaces are not handled consistently by Informix and Oracle, and can result in errors when switching the underlying database

N/a

R#27065

Scroll bar is not scrolled in the Description tab in the Work Pane of a Task when clicking the down arrow key

N/a

R#27202

A scroll bar is needed on the Task Properties dialog when many custom attributes are shown

N/a

R#27365

typedef -import should work for users in type_developer role

N/a

R#27394

After upgrade, ccmadm userdomain fails on Windows until the services are restarted

N/a

R#27514

Unhandled Runtime Exception when trying to open the release properties dialog from the context menu of a release-specific process rule which is not modifiable in the current database and whose corresponding release was deleted

N/a

R#27981

Error "Incorrect parameter : BUFFERS" can occur when running ccmsrv modify

N/a

R#28001

The Synergy client does not disable editing files whose "editor" setting is set to FAIL in ccm.properties

N/a

R#28117

Leftover recon_temp (reconfigure template) objects whose associated release was deleted cause upgrade to fail

N/a

R#28169

Developers can select "Integration Testing" purpose when copying a project, which results in a working project with purpose "Integration Testing"

N/a

R#28233

Keyword expansion does not expand all keywords correctly during ccm move command

N/a

R#28688

It should be possible to create a baseline from a non-local (DCM-transferred) project

N/a

R#28733

The Synergy Windows client always translates new lines in ASCII files for temporary files during compare/merge

N/a

R#28829

In a LOWER Case database, the DCM ID can be uppercase which causes problems with version strings

N/a

R#28849

Modifying the attrange.dft file's task:platform setting affects platform choices for all types, not just task

N/a

R#28875

Errors occur while starting a Synergy session when the database path is longer than 47 characters

N/a

R#28877

The Eclipse integration cannot connect to Synergy when Eclipse is started with the -Duser.home JVM option

PK98159

R#28991

Cannot add an object to a directory whose name includes the delimiter when allow_delimiter_in_name is set to TRUE

N/a

R#29115

The Informix database server fails to start with a permission error

PK82909

R#29242

Interactive merge returns contents of the first file selected when supertype is binary, even if the type has a merge command defined

PM00394

R#29367

Changing a prep project's version mistakenly changes the version for subprojects with non-matching release values

N/a

R#29385

Adding a large project to a transfer set gives error "ORA-01795: maximum number of expressions in a list is 1000"

N/a

R#29552

DCM should transfer generic process rules automatically when appropriate

N/a

R#29602

Incorrect permissions left on onconfig file when using ccm_install -u

N/a

R#29847

Copy project is ignoring “Allow subprojects to be replaced” setting when updating projects

N/a

R#29976

Creating a prep project gives errors on a Linux client when the user is in more than 32 groups on Linux

N/a

R#29985

DCM events are not always logged when running multiple DCM generates in parallel

N/a

R#30090

Changes in the Process Rule Properties dialog can cause the baseline query to stop working

N/a

R#30129

Process Rule Properties dialog does not give a good message if you select "Specific baseline" but do not choose a baseline, then try to save

N/a

R#30172

A user reconciling a shared work area should be notified if some files are not updated in the database because the user does not have permissions to change them

N/a

R#30173

Wildcards do not work for the component name when querying for a release

N/a

R#30343

A merged object with release "n+1" can be automatically used in the project release "n"

N/a

R#30361

DCM receives packages for tset in order of destination dbid, not in the order generated

N/a

R#30542

The 'Baseline Project' data displayed in the History of a Project is incorrect

N/a

R#30551

Starting Synergy java client on UNIX prompts for password when using ESD and a proper .ccmrc file, even though it has the password

N/a

R#30647

The command 'ccm process_rule -copy' fails if the 'to' option is not specified

N/a

R#30787

Changing work area to an already existing path fails, but fails to revert back to the previous valid path

N/a

R#30834

The bsddff3 merge program pops up a command prompt on Windows

N/a

R#30880

The Synergy project pane gives a tree error if the first column is not 'Name'

N/a

R#31043

ccm merge on a file with spaces in the name can delete other files in the work area

N/a

R#31093

Setting the %start_day_of_week option does not change the results of "Tasks Completed Last Week"

N/a

R#31127

ccm monitor creates temp files and doesn't clean up afterwards

N/a

R#31180

A task's context menu does not always show the "Cut" option in the Change Request Explorer

N/a

R#31262

It should be possible to redirect 'ccmdb upgrade' log file to different filenames

N/a

R#31793

Unable to explore a directory or edit a file from Synergy GUI when directory name contains certain Chinese (GB18030) characters

PK81322

R#31838

The permissions to several files in the Synergy installation are too open on UNIX/Linux

N/a

R#32145

Synergy GUI refresh sometimes blocks for a few seconds at start of update operation

N/a

R#32274

Password policy messages should be translatable

N/a

R#32406

Incorrect warning when changing purpose of project in Java GUI

N/a

R#32431

Table columns should use case insensitive sorting for string attributes

N/a

R#32625

Logs downloaded from server are not being cleaned up

N/a

R#32627

DCM receive reports error when another session receives a package

PK84760

R#32719

Unhandled Runtime Exception during Synergy Web Mode startup after first specifying wrong startup parameters, and then specifying corrected startup parameters

PK84970

R#32778

Type displayed in the Synergy project pane does not get updated when you use a different version of a directory that contains a file with the same name but a different type

N/a

R#32795

The full name for a process rule should use ":" instead of the version delimiter so the name is not ambiguous (for scripting purposes)

PK85301

R#32811

The use_static_wa option is not used by the Synergy GUI in Web Mode

N/a

R#32816

Toggling the "show only successors/predecessors" button in the History dialog clears selected objects and loses user's context

N/a

R#32845

If the Change server (Central Server mode) is shut down, it can block the Synergy GUI from looking up a task's associated objects

N/a

R#32876

The release explorer shows all available process rules instead of all valid process rules

N/a

R#32947

Querying for projects on the Baseline Projects tab of the Process Rules Properties continues to return the same projects after changes to query until you reopen the dialog

N/a

R#32971

The Change Type operation fails in Web Mode

N/a

R#32974

Release Favorites in the options dialog does not list inactive releases

N/a

R#32976

Product component tasks are shown in the create and add folder for component dialog even when the query is set to Projects only

N/a

R#32988

The Select Baseline dialog queries for "Component/*" when no component is selected, in the Create and Add Folder for Component dialog

N/a

R#32994

Use of absolute subprojects in Unix new work areas might delete the unused subproject's work area

N/a

R#33006

Selecting "Keep work area change" on a symlink in the new work area can cause infinite recursion

N/a

R#33009

Parallels are reported on rejected objects when resolving work area changes

N/a

R#33017

Synergy work area in Web Mode gives errors if the user's Windows desktop is using the FDCC standard

N/a

R#33033

Unprotected custom attributes of type up* (upstring, upboolean, etc.) should be modifiable in Synergy GUI on objects in static state

N/a

R#33037

Component task transition does not show up in the status log

N/a

R#33038

Can't rename a purpose from Java GUI

N/a

R#33058

Error when changing UNIX link-based work area to Windows work area in Web Mode

N/a

R#33102

Typo in usage message for ccmdb command

N/a

R#33107

Warning message when checking in objects only bound in a project without a maintained work area

N/a

R#33119

ccm_copy_tools gives incorrect error message

N/a

R#33126

Arguments have no effect on ccm soad –delete –scope command (new CLI)

N/a

R#33147

The "For" combo box in "Create and Add Folder for Component" is not behaving properly

N/a

R#33153

Changing the Component Tasks property on the Release Properties dialog causes an assert

N/a

R#33155

Java CLI query gives an ACcent abort error when the DISPLAY is invalid

N/a

R#33156

The ccm sync command in Synergy CLI doesn't sync out a partial missing work area

N/a

R#33158

Invalid value to ccm process -show diagram reports an Unhandled Runtime Exception

N/a

R#33159

When ccm process -cp command fails in new CLI, it gives the message "Operation failed: see message view"

N/a

R#33178

The ccm sync command in the Synergy CLI is not consistent with Classic CLI

N/a

R#33180

The ccmdb unpack command's usage message contains a typo

N/a

R#33188

In the new CLI, dcm -modify does not detect the value supplied to its option /directory

N/a

R#33189

Release Favorites has some issues with selecting releases

N/a

R#33191

ccm release –modify command always sets ‘Parallel Check In’ to ‘No’ if option –allow_parallel_check_in is not specified

N/a

R#33200

Create Baseline fails if the project grouping includes component tasks

N/a

R#33206

ccm release –create –from rel/1.0 ignores –allow_parallel_check_in option, if rel/1.0 does not allow_parallel_check_out

N/a

R#33208

Issues with Web Mode authentication in corporate mode (RDS)

N/a

R#33210

ccm fsck prints 'No server for ArchiveExtract requests' multiple times

N/a

R#33211

DCM Generate/Receive on Windows running against a UNIX database fails

N/a

R#33213

"ccm srv modify -u" command ignores the -Y flag

N/a

R#33215

ccm process -show output format is inconsistent with other commands

N/a

R#33217

If copying attributes from one object to another from Synergy CLI and classic CLI fails, it returns mismatching object names for from and to fields in the error messages

N/a

R#33220

The database path in the output of ccmdb create command has "/db/db" instead of "/db"

N/a

R#33225

For any types that have a local no_copy_on_derive setting, the setting is ignored in 7.1

 

N/a

R#33229

Releases found by auto-complete are added as favorites while typing in the release field

 

N/a

R#33231

Unable to type release in release field due to auto-complete removing what is typed

 

N/a

R#33232

The Attachments table in the Submit Support Request Dialog opens a wrong files when double clicking on entries after the table is sorted by clicking on the column headers

 

N/a

R#33235

In the History view, the 'Show Successors and Predecessor' button does not turn off when the refresh button is pressed

 

N/a

R#33240

Network errors cause the router to stop responding

 

PK87642

R#33241

Deleting a release value does not put a message in the user interface log

 

N/a

R#33247

ccm task –fix gives an Unhandled Runtime Exception error for registered tasks

 

N/a

R#33248

ccm task –copy gives an Unhandled Runtime Exception error for registered tasks

 

N/a

R#33252

Trying to add a folder template to a release-specific process fails from the Synergy CLI

 

N/a

R#33260

"ccm cr_summary" commands gives innacurate sizes for some of the attachments

 

N/a

R#33262

Create and Add Folder for Component dialog shows inactive releases

 

N/a

R#33264

ccm task –copy fails if the –default option is specified for a source task with different resolver

 

N/a

R#33271

The ccm archive_fix command with the -fast option gives an ACcent abort error if all specified objects are skipped

 

N/a

R#33286

The ccm attribute show command fails for attributes with the ‘float’ type

 

N/a

R#33287

The ccm attribute show command fails for attributes with the ‘integer’ type with a null value

 

PK88072

R#33289

The Copy Project dialog layout has issues if its width is less than 540px

 

N/a

R#33312

In Synergy CLI, relate/unrelate fail if the object is static, even for users in the ccm_admin role

 

N/a

R#33329

The History dialog mini-view should use memory more efficiently

 

N/a

R#33335

Copying a large project hierarchy can fail in Web Mode when projects contain multiply-bound objects

 

N/a

R#33355

Changing the version on a checked out file fails in link-based work areas in Web Mode

 

N/a

R#33364

Files get keywords expanded when they're not supposed to when using the Synergy Eclipse integration

 

N/a

R#33379

ccm diff -vc release/spec or process_rule_spec fails from Java CLI

 

N/a

R#33394

Improve encryption for the ccmrc file

 

N/a

R#33400

ccm edit on a process rule or release spec sometimes gives an "Operation failed" message from the new CLI

 

N/a

R#33401

"Invalid component name" message appears in Create and Add Folder for Component dialog for some valid component names

 

N/a

R#33425

Synergy Merge Dialog for file objects still contains Telelogic name in the title bar as "Telelogic Synergy Merge"

 

N/a

R#33429

Checking in a file from the Visual Studio IDE fails in web mode

 

N/a

R#33430

Work Area is not updated when selecting a modifiable subproject through "Use Version" in Web Mode

 

N/a

R#33440

Need a command line way to set the server url on Synergy 7.1

 

N/a

R#33470

The list of types in the Change Type dialog is not sorted

 

N/a

R#33471

The clean_cache command cannot be interrupted

 

N/a

R#33491

Add support for additional locales required by IBM on Solaris (added ICU4J library)

 

N/a

R#33515

Integrations are unable to bring Synergy GUI windows to the front without some manual interaction

 

N/a

R#33521

"ccm dcm -show -el -index 0 -info" displays Chinese Data incorrectly

 

N/a

R#33534

When a project name includes Chinese characters, the 'ccm use -project' command fails

 

N/a

R#33538

Synergy CLI reports missing ccm.cli.ls.any.format preference

 

N/a

R#33554

Synergy CLI ccm dir -m shows uncontrolled file as type symlink

 

N/a

R#33556

Synergy CLI ccm ls and ccm dir show wrong header for directory

 

N/a

R#33557

Prompt to unexclude a task that was fixed only shows the task number

 

PK91744

R#33565

Checking out an object displays non leaf parallel objects

 

N/a

R#33575

Update fails to update some files in the work area when multiple Build Managers are using the same prep project

 

N/a

R#33588

Need to prompt user to exit session after closing the Submit Request dialog after an Unhandled Runtime Exception occurs

 

N/a

R#33649

After upgrading a database from release 6.6a or 6.5a, Synergy sessions do not start in Web mode unless the CCM Server is restarted

 

N/a

R#33657

The ccm attribute -copy command can result in string attributes that contain newlines

 

N/a

R#33677

DCM receive should detect a package generated from a database with the same id as the receiving database

 

N/a

R#33727

Accessibility: Ctrl+H doesn't work if clicked in Welcome tab

 

PK94428

R#33796

Unresolvable work area conflict after deleting files from file system on Windows

 

N/a

R#33824

Task's modify_time gets changed when a baseline is published

 

N/a

R#33829

Work area errors during Copy Project with relative static subprojects

 

N/a

R#33830

Deleting a another user's subproject as ccm_admin also attempts to delete the root directory when it shouldn't

 

N/a

R#33832

Running ccmdb upgrade -w twice in a row produced error messages

 

PK95841

R#33931

Maintaining the _relations attribute on checked out projects is causing unnecssary entries in the attrib table

 

N/a

R#33943

The date format on the project's properties dialog is different from the one shown in the work pane

 

N/a

R#33977

DCM transfer logs DCM event with from dbid instead of to dbid

 

N/a

R#34064

ccm checkpoint command creates a new working version, if the user specifies multiple objects with state ‘integrate’

 

N/a

R#34111

Upgrading Synergy from 6.5 to 7.1 can cause duplicate project groupings

 

N/a

R#34140

In Web Mode after DCM receive, sync does not create links to subprojects under the top-level project

 

N/a

R#34161

Some translated labels are truncated on the "Create and Add Folder for Component" dialog

 

N/a

R#34210

Synergy server fails to authenticate users after RDS authentication time-out with the LDAP server

 

N/a

R#34290

ccm task -create -default -q shows additional information beyond just the task created

 

N/a

R#34368

DCM receive can result in a folder template, process rule, process or release being overwritten with older data

 

PM01665

R#34394

Network errors can cause intermittent ACcent aborts in the Synergy client using Web Mode

 

N/a

R#34397

Creation of prep project does not set the root dir to be group writable in the new work area

 

PK99813

R#34439

Project checkout with update turned on binds old static subprojects even if the subproject was replaced by Update

 

N/a

R#34496

Source file keywords are not expanded in Synergy 7.1 Web Mode

 

N/a

R#34550

Issues sync'ing work area changes in a copy-based work area on shared projects in Web Mode

 

PM00788

R#34557

Synergy client in Web Mode crashed with ConcurrentModificationException while deleting objects

 

PM01654

R#34614

Synergy 6.5 to 7.1 DCM fails if there are trailing spaces in certain fields

 

N/a

R#34634

Security concerns with changing RDS password from Synergy

 

N/a

R#34695

Users in ccm_admin role should be able to set the release attribute from the CLI even if the release does not exist (for repair purposes)

 

N/a

R#34750

Showing Folder properties a second time doesn't refresh the associated tasks

 

N/a

R#34751

After being modified via the Classic GUI, queries in folders and folder templates can display incorrectly in the Synergy GUI

 

PM02629

R#34800

ascii files containing character 0d (e.g., Mac OS newline characters) are corrupted by sync in Web Mode

 

PM03064

R#34854

Showing a project's history after creating a baseline can result in an Unhandled Runtime Exception

 

The following problems were fixed in Rational Synergy Fix Pack 7.1.0.2. Note that Fix Pack 7.1.0.2 also includes all fixes from iFix 7.1.0.1.03.

APAR

CR ID

Synopsis

N/a

R#27994

The red diamond on the Task Properties Change Requests tab that indicates a CR is required is not cleared after a CR is added.

PM10136

R#35760

When a user tries to start a 7.1 client against a 7.1.0.1.01 server and database, the GUI gives an unhandled runtime exception. Instead it should give a message that the client and server versions are not compatible.

PM11073

R#35922

After a network outage between the Synergy server and RDS, starting Synergy Web Mode sessions fails for users with the erroneous message "Invalid user or password"; the Synergy Web Server needs to be restarted before users can login.

PM11593

R#36025

The Current Task is sometimes displayed only as a series of dots (ellipses).

PM15209

R#36537

On the Project Grouping context menu, "Automatically Update Baseline & Tasks" is unchecked the first time it is opened.

PM15784

R#36650

The Submit Support Request dialog always shows the synergy.log file in the default path, even if the file does not yet exist or is in a different location.

PM16348

R#36848

Expanding keywords for empty attributes puts a space in the source file.

PM16887

R#36932

DCM receive fails to transition a baseline to the correct state (for example, released) if the transition is not permitted in that database.

PM17007

R#36957

If a user changes his or her password via DOORS or Change with a Synergy session running, Synergy operations start to fail without giving a good message. When this happens, users should be required to login again.

N/a

R#36988

If a user changes his or her password and the RDS server is restarted a short time later, Synergy sessions fail to start with the message "Invalid user or password" even when using the correct user and password.

PM17272

R#36996

The root directory of a Windows drive (e.g., "C:\") cannot be used as a work area path

N/a

R#37073

"Compare with Predecessor" for an ascii object with more than one version fails with the message "Workarea modification disallowed"

PM18190

R#37140

On UNIX with a Synergy Web Mode client, in a copy-based project hierarchy with relative work areas, when the update operation selects a different version of a static subproject, it fails with the message "Unable to remove work area symbolic link for subproject"

N/a

R#37142

If Synergy login fails because the RDS password has expired, Synergy should give a message to that effect rather than giving the message "Invalid user or password." (See also RFE 6598.)

PM18316

R#37149

The Synergy "ccmsrv restore" command with the option '-y' prompts the user for confirmation. The purpose of the -y flag is to proceed running the command without prompting.

N/a

R#37179

Checking in a file to the checkpoint state using the new Synergy CLI fails with the message "Couldn't remotely chmod"

PM18795

R#37202

An Unhandled Runtime Exception occurs when you create an object of a type that was recently created by another user since your Synergy session was started.

N/a

R#37289

The "ccm make" command hangs on Windows in the new Synergy CLI with Synergy iFix 7.1.0.1.03 installed.

PM19299

R#37295

ESD authentication fails caused by interrupts to the ESD process. Synergy should handle ESD interruptions rather than treating this case as a fatal error.

N/a

R#37320

When starting a process from a user-defined Synergy menu extension, the PATH environment variable is set incorrectly if it is not all upper case.

PM19806

R#37384

After you create a new release and then delete it, you cannot create another new release using the same component name, because it requires you to enter a baseline release but none exists

PM20040

R#37395

When sync'ing new files into Synergy through the graphical interface, the label in the Task Explorer is truncated

PM20044

R#37399

When doing a "copy to file system" for a large project hierarchy, Synergy Web Mode gives an ACcent error if a cache file cannot be found due to an NFS caching delay.

PM20479

R#37453

In the new Synergy CLI, the "ccm -pr copy" command (copying a process rule) fails when copying from a process rule that has the baseline setting set to "Specific Baseline."

PM20818

R#37523

Synergy gives an Unhandled Runtime Exception while sorting the Sync dialog on the "Is a product" column.

PM21296

R#37595

The Synergy-Eclipse integration (with Web Mode) gives an Unhandled Runtime Exception when doing a team sync operation from Eclipse, when sync is configured to filter on products but the work area contains no products.


Contacting Support

Please visit our Telelogic support overview site at: http://www.ibm.com/software/rational/support/telelogic/
You will find a one-sheet reference guide about how to best contact support in your geography.


 

Notices

This information was developed for products and services offered in the U.S.A. IBM may not offer the products, services, or features discussed in this document in other countries. Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead. However, it is the user's responsibility to evaluate and verify the operation of any non-IBM product, program, or service.

IBM may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not grant you any license to these patents. You can send written license inquiries to:

IBM Director of Licensing
IBM Corporation
North Castle Drive

Armonk, NY 10504-1785
U.S.A.


For license inquiries regarding double-byte character set (DBCS) information, contact the IBM Intellectual Property Department in your country or send written inquiries to:

IBM World Trade Asia Corporation
Licensing
2-31 Roppongi 3-chome, Minato-ku
Tokyo 106-0032, Japan

The following paragraph does not apply to the United Kingdom or any other country where such provisions are inconsistent with local law:
INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer of express or implied warranties in certain transactions. Therefore, this statement may not apply to you.

This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. IBM may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice.

Any references in this information to non-IBM websites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites. The materials at those websites are not part of the materials for this IBM product and use of those websites is at your own risk.

IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you. Licensees of this program who wish to have information about it for the purpose of enabling: (i) the exchange of information between independently created programs and other programs (including this one) and (ii) the mutual use of the information which was exchanged, should contact:

Intellectual Property Dept. for Rational Software
IBM Corporation
1 Rogers Street
Cambridge, Massachusetts 02142
U.S.A.

Such information may be available, subject to appropriate terms and conditions, including in some cases, payment of a fee.

The licensed program described in this document and all licensed material available for it are provided by IBM under terms of the IBM Customer Agreement, IBM International Program License Agreement or any equivalent agreement between us.

Any performance data contained herein was determined in a controlled environment. Therefore, the results obtained in other operating environments may vary significantly. Some measurements may have been made on development-level systems and there is no guarantee that these measurements will be the same on generally available systems. Furthermore, some measurements may have been estimated through extrapolation. Actual results may vary. Users of this document should verify the applicable data for their specific environment.

Information concerning non-IBM products was obtained from the suppliers of those products, their published announcements or other publicly available sources. IBM has not tested those products and cannot confirm the accuracy of performance, compatibility or any other claims related to non-IBM products. Questions on the capabilities of non-IBM products should be addressed to the suppliers of those products.

This information contains examples of data and reports used in daily business operations. To illustrate them as completely as possible, the examples include the names of individuals, companies, brands, and products. All of these names are fictitious and any similarity to the names and addresses used by an actual business enterprise is entirely coincidental.

If you are viewing this information softcopy, the photographs and color illustrations may not appear.

Trademarks

IBM, the IBM logo, and ibm.com are trademarks or registered trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at Copy and Trademark information at www.ibm.com/legal/copytrade.html.

Adobe, the Adobe logo, PostScript, and the PostScript logo are either registered trademarks or trademarks of Adobe Systems Incorporated in the United States, and/or other countries.

IT Infrastructure Library is a registered trademark of the Central Computer and Telecommunications Agency which is now part of the Office of Government Commerce

Intel, Intel logo, Intel Inside, Intel Inside logo, Intel Centrino, Intel Centrino logo, Celeron, Intel Xeon, Intel SpeedStep, Itanium, and Pentium are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries.

Linux is a registered trademark of Linus Torvalds in the United States, other countries, or both.

Microsoft, Windows, Windows NT, and the Windows logo are trademarks of Microsoft Corporation in the United States, other countries, or both.

ITIL is a registered trademark, and a registered community trademark of the Office of Government Commerce, and is registered in the U.S. Patent and Trademark Office

UNIX is a registered trademark of The Open Group in the United States and other countries.

Cell Broadband Engine is a trademark of Sony Computer Entertainment, Inc. in the United States, other countries, or both and is used under license therefrom.

Java and all Java-based trademarks and logos are trademarks of Sun Microsystems, Inc. in the United States, other countries, or both.