Table 17 describes power error messages and their suggested actions.
Note: | You will need to connect a keyboard and monitor to your appliance in order to see error messages. |
Table 17. Power errors and actions
Message | Meaning | Action | ||
---|---|---|---|---|
Power supply X current fault | Level-critical; excessive current demand on power supply X | See "Power checkout". | ||
Power supply X DC good fault | Level-critical; power good signal not detected for power supply X | Replace power supply X. | ||
Power supply X fan fault | Level-critical; fan fault in power supply X | Replace power supply X | ||
Power supply X fault | Level-critical; overcurrent condition exists | See "Power checkout". | ||
Power supply X 12V fault | Level-critical; overcurrent condition detected | See "Power checkout". | ||
Power supply X 3.3V fault | Level-critical; 3.3V power supply X had an error | See "Power checkout". | ||
Power supply X 5V fault | Level-critical; 5V power supply X had an error | See "Power checkout" . | ||
System over recommended X current | Level-non-critical; system running too much current on that voltage | See "Power checkout". | ||
System running non-redundant power | Level-non-critical; system does not have redundant power |
| ||
System under recommended voltage for X v | Level-warning; indicated voltage supply under nominal value; value for X can be +12, -12, or +5 |
| ||
System under recommended voltage on 3.3 v | Level-warning; 3.3 volt supply under nominal value |
| ||
System under recommended X current | Level-non-critical; system drawing less current than recommended on voltage X | See "Power checkout". | ||
X V bus fault | Level-critical; overcurrent condition on X voltage bus |
| ||
12V X bus fault | Level-critical; overcurrent condition on 12-V X voltage bus |
| ||
5V fault
| Level-critical; overcurrent condition on 5-V subsystem |
| ||
240 VA bus fault | Level-critical; overcurrent or overvoltage condition in power subsystem. | See "Power checkout". |