Service Guide


System shutdown

Refer to Table 18, Table 19, Table 20, Table 21, and Table 22, when experiencing system shutdown related to voltage or temperature problems.

Voltage related system shutdown

Table 18 describes voltage related system shutdowns, their meanings, and suggested actions.

Table 18. Voltage related shutdown messages and actions
Message Meaning Suggested Action
System shutoff due to X current over max value Level-critical; system drawing too much current on voltage X bus See "Power checkout".
System shutoff due to X current over min value Level-critical; current on voltage bus X under minimum value See "Power checkout".
System shutoff due to X V over voltage Level-critical; system shutoff due to X supply over voltage
  1. Check power supply connectors
  2. Replace power supply
  3. Replace power backplane

System shutoff due to X V under voltage Level-critical system shutoff due to X supply under voltage
  1. Check power supply connectors.
  2. Replace power supply
  3. Replace power backplane

System shutoff due to VRM X over voltage
  1. Replace power supply
  2. Replace power supply backplane

Temperature related system shutdown

Table 19 describes temperature-related shutdown messages and suggested actions.

Table 19. Temperature related shutdown messages and suggested actions
Message Meaning Suggested Action
System shutoff due to board over temperature Level-critical; board is over temperature
  1. Ensure system is being properly cooled, see Appendix E, "Specifications".
  2. Replace board

System shutoff due to CPU X over temperature Level-critical; CPU X is over temperature
  1. Ensure system is being properly cooled, see Appendix E, "Specifications" .
  2. Replace CPU X

System shutoff due to CPU X under temperature Level-critical; CPU X is under temperature Ambient temperature must be within normal operating specifications; see Appendix E, "Specifications".
System shutoff due to DASD temperature (sensor X) Level-critical; DASD area reported temperature outside recommended operating range Ensure system is being properly cooled, see Appendix E, "Specifications".
System shutoff due to high ambient temperature Level-critical; high ambient temperature Ambient temperature must be within normal operating specifications; see Appendix E, "Specifications".
System shutoff due to system board under temperature Level-critical; system board is under temperature Ambient temperature must be within normal operating specifications; see Appendix E, "Specifications".