Final Release of Patch V85S-4 Only applicable to V85S-1 Code Build Stream Pre-requisite patches V85S-2, V85S-3 must be installed prior to this patch. Note: You CANNOT install this patch into V85S-0 build. *************** COMPAQ COMPUTER CORPORATION – DISCLAIMER ************** * In accordance to Compaq's commitment to maintain the highest level * * of customer satisfaction, this patch is being provided to customers * * who have purchased the referenced Storageworks product that is * * currently covered by one of Compaq's extensive warranty plans and * * is also provided to those customers not yet underCompaq's extended * * warranty plan as a courtesy. The availability of this patch is in * * no way an obligation by Compaq to continue this practice in the * * future. * *********************************************************************** ****************************** WARNING ******************************** * * * - Please be sure to cut and paste EXACTLY as indicated. Any * * addition or subtraction of pertinent patch data will mean the * * patch will not load due to a checksum failure and the controller * * will remain at it's original version. * * * * - As always, any critical data should be backed up prior to * * performing any updates. * *********************************************************************** PATCH V85S-4 Patch Title: Don’t log UA to only CCL install HSOF Version: HSG80 V85S Patch Number: 4 Date: MARCH 5, 2000. I. Patch Description: The HSG80 controller crashes with a Last Failure Code of 02DD0101. During processing of show (unit, storage, disks) type of commands, ACS memory resources are not properly released after completion of the command processing. This occurrence of crashing the controller is greatly accelerated by the number and frequency of 'show unit status' requests made of the controller. These commands may be received either via the CLI port on the HSG80 controller or via the ‘send/receive diagnostic’ commands of the SWCC agent. PATCH_V85S-4.TXT;1 Title: Deallocate data buffers after use Version: V85S Length: 183 Patch Type: 0 Patch Number: 4 Count: 2 Address: C0090FDC Value[ 0]: 84003000 Value[ 1]: C0FFF390 Count: 8 Address: C0FFF390 Value[ 0]: 32012010 Value[ 1]: 8C811000 Value[ 2]: 86003000 Value[ 3]: C0089760 Value[ 4]: 82F1607C Value[ 5]: 5C801606 Value[ 6]: 84003000 Value[ 7]: C0090FE4 Count: 2 Address: C006E9E4 Value[ 0]: 84003000 Value[ 1]: C0FFF3B0 Count: 10 Address: C0FFF3B0 Value[ 0]: 32012010 Value[ 1]: 8C811000 Value[ 2]: 86003000 Value[ 3]: C0089760 Value[ 4]: 80A1E078 Value[ 5]: 3555200C Value[ 6]: 84003000 Value[ 7]: C006E9EC Value[ 8]: 84003000 Value[ 9]: C006EA54 Count: 2 Address: C00708AC Value[ 0]: 84003000 Value[ 1]: C0FFF3E0 Count: 6 Address: C0FFF3E0 Value[ 0]: 9021631C Value[ 1]: 5C401610 Value[ 2]: 320A2008 Value[ 3]: 8C200000 Value[ 4]: 84003000 Value[ 5]: C00708B4 Count: 1 Address: C00708C4 Value[ 0]: 35A5404C Count: 1 Address: C00708D8 Value[ 0]: 35850038 Count: 0 Verification: FCCE74A8 II. Patch Installation Script for use with a host to CLI Utility Extract the following script to file PATCH_V85S-4.script. Submit script to CCL via HSZterm utility. ----- Begin Script ----- ! !Deallocate data buffers after use ! run clcp 2 1 y V85S 183 0 4 2 C0090FDC 84003000 C0FFF390 8 C0FFF390 32012010 8C811000 86003000 C0089760 82F1607C 5C801606 84003000 C0090FE4 2 C006E9E4 84003000 C0FFF3B0 10 C0FFF3B0 32012010 8C811000 86003000 C0089760 80A1E078 3555200C 84003000 C006E9EC 84003000 C006EA54 2 C00708AC 84003000 C0FFF3E0 6 C0FFF3E0 9021631C 5C401610 320A2008 8C200000 84003000 C00708B4 1 C00708C4 35A5404C 1 C00708D8 35850038 0 FCCE74A8 3 0 ----- End Script ----- III. Patch Installation Script for use with SCU (Unix only) download utility: Extract the following script to PATCH_V85S-4.TXT and execute it using SCU. ----- Begin Script ----- ! !Deallocate data buffers after use ! run clcp 2 1 y V85S 183 0 4 2 C0090FDC 84003000 C0FFF390 8 C0FFF390 32012010 8C811000 86003000 C0089760 82F1607C 5C801606 84003000 C0090FE4 2 C006E9E4 84003000 C0FFF3B0 10 C0FFF3B0 32012010 8C811000 86003000 C0089760 80A1E078 3555200C 84003000 C006E9EC 84003000 C006EA54 2 C00708AC 84003000 C0FFF3E0 6 C0FFF3E0 9021631C 5C401610 320A2008 8C200000 84003000 C00708B4 1 C00708C4 35A5404C 1 C00708D8 35850038 0 FCCE74A8 3 0 ----- End Script ----- IV. Patch Deletion Script for use with SCU (Unix only) download utility: Extract the following script to PATCH_V85S-4_DELETE.WB_DATA and execute it using SCU. ----- Begin Script ----- ! Deallocate data buffers after use delete (c) DEC 23-Feb-2001 ! 2 V85S 4 ----- End Script ----- V. Patch file for use with SWCC Client's Update Controller Software feature. Transfer the attached file PATCH_V85S-4_INSTALL.WB_DATA to the Client host and specify it in the 'File to load' box from the SWCC Update Controller Software screen as selected via the 'Storage' menu option. ----- Begin swcc Script ----- ! Deallocate data buffers after use install (c) DEC 23-Feb-2001 ! 1 V85S 183 0 4 2 C0090FDC 84003000 C0FFF390 8 C0FFF390 32012010 8C811000 86003000 C0089760 82F1607C 5C801606 84003000 C0090FE4 2 C006E9E4 84003000 C0FFF3B0 10 C0FFF3B0 32012010 8C811000 86003000 C0089760 80A1E078 3555200C 84003000 C006E9EC 84003000 C006EA54 2 C00708AC 84003000 C0FFF3E0 6 C0FFF3E0 9021631C 5C401610 320A2008 8C200000 84003000 C00708B4 1 C00708C4 35A5404C 1 C00708D8 35850038 0 FCCE74A8 ----- End swcc Script -----