Service Guide


Temperature error messages

Table 15 describes temperature error messages, their meanings, and suggested actions.
Note:You will need to connect a keyboard and monitor to your appliance in order to see error messages.

Table 15. Temperature errors and actions
Error Message Meaning Suggested Action
DASD X Over Temperature Level-critical; Direct Access Storage Device bay X was over temperature Ensure system is being properly cooled; see Appendix E, "Specifications".
DASD X Over recommended Temperature Level-warning; DASD bay X had over temperature condition Ensure system is being properly cooled; see Appendix E, "Specifications".
DASD X under recommended temperature

Level-warning; direct access storage device bay X had under temperature condition Ambient temperature must be within normal operating specifications; see Appendix E, "Specifications".
DASD 1 Over Temperature Level-critical; sensor for DASD1 reported temperature over recommended range Ensure system is being properly cooled; see Appendix E, "Specifications".
Power Supply X Temperature Fault Level-critical; power supply X had over temperature condition
  1. Ensure system is being properly cooled; see Appendix E, "Specifications" .
  2. Replace Power Supply X.

System board is over recommended temperature
  1. Ensure system is being properly cooled; see Appendix E, "Specifications".
  2. Replace the system board.

System board is under recommended temperature
Ambient temperature must be within normal operating specifications; see Appendix E, "Specifications".
System over temperature for CPU X

Level-warning; CPU X reporting over temperature condition

Ensure system is being properly cooled; see Appendix E, "Specifications".
System under recommended CPU X temperature Level-warning; system reporting under temperature condition for CPU X Ambient temperature must be within normal operating specifications; see Appendix E, "Specifications".


[ Top of Page | Previous Page | Next Page | Table of Contents | Index ]